Roofing & roof material products for house roofing
Cedar wood shake and cedar shingle roof material
Certi-Sawn™ Taper Sawn Cedar Shakes

Certi-Sawn shake

Number 1 Grade
Description - Lengths 18 inch, 24 inch; width 4" minimum, 14" maximum; thickness 5/8" nominal (5/8" to 1", yet uniform in each bundle or pallet).  Face 100% clear.  Flat grain 10% maximum, cross grain minimum allowed. Roof Exposure - 10" for 24 inch shake; 7½" for 18 inch shake.

Wall exposure - Single course: 11½" for 24 inch shake; 8½" for 18 inch shake. Double course: 18" for 24 inch shake; 14" for 18 inch shake.

Recommended Use - For walls or roofs on 4:12 pitch and steeper where a high quality, durable and uniform appearance is desired.

Starter-finish Course - Length 15 inch.  For use on the underlying starter course at eave lines and for the final course at ridges where trimming would otherwise be necessary and full-length shakes are not needed.

Premium Grade
Description - Same as No. 1 Grade, 100% edge grain.  All other descriptions from No.1 Grade apply.

Number 2 Grade
Description - Lengths 18 inch, 24 inch; width 3" minimum, 14" maximum; 2 thicknesses - ½" to ¾" to 1¼" (yet uniform in each bundle or pallet). * Lower half of face is clear.  Flat and cross grains allowed.  Tight knots and other limited defects allowed in top half of shake.

*1991 ICBO Uniform Building Code requires No.2 grade taper-sawn shakes having two thicknesses at the butt; 5/8" or ¾" with a minus tolerance of 1/16"

Roof Exposure - 7½" for 24 inch shake; 5½" for 18 inch shake.

Wall Exposure - Single course - 10" for 24 inch shake; 7½" for 18 inch shake.
Double course: 11½" for 24 inch shake; 8½" for 18 inch shake.

Recommended Use - For walls or roofs 4:12 pitch or steeper and where a good quality appearance is desired.

Number 3 Grade
Description - Lengths 18 inch, 24 inch; width 3" minimum, 14" maximum; thickness ½" nominal (½" to 1¼", yet uniform in each bundle or pallet).  Face sound and serviceable.  Flat and cross grains allowed.  Limited knots and defects allowed on the entire face.

Roof Exposure - Not recommended for roofs of human occupied buildings. 7½" for 24 inch shake; 5½" for 18 inch shake. 12:12 pitch minimum.

Wall Exposure - Single course: 10" for 24" shake; 7½" for 18 inch shake.
Double course: 11½" for 24 inch shake; 8½" for 18 inch shake.

Recommended Use - For walls where a rustic, knotted appearance is acceptable.

  • Class A, B & C fire rating may be obtained by specifying Certi-Guard permanent fire retardant Certi-Sawn shakes.
  • Certi-Last treated shakes are available for added longevity and come with a 30 year warranty against rot and fungal decay.
  • Products manufactured by members of the Cedar Shake & Shingle Bureau are graded in accordance with UBC Standard No. 32-8 and/or CSA 0118.1
E-Mail us for exact specifications and descriptions.

Back to Products Page


© Fire Smart Roofing 2004 | Disclaimer | Site Map
Web design in Vancouver by Graphically Speaking


For roof material call Fire Smart Roofing
For roof material email Fire Safe Roofing
Shingle roofing material information
Cedar shingle roof material information
Roof and roofing info